ChemLogic CL4 Four-Point Gas Detector

Contact Us
In stock
SKU
2-500-200

The CL4 highlights our series of flagship ChemLogic® systems for multipoint, colorimetric low-level gas detection. This robust system provides continuous detection of toxic and corrosive target gases - at up to four specified points. ChemLogic systems are engineered and designed to provide an essential life-safety role with accurate and interference-free results. 

The ChemLogic CL4 additionally offers streamlined installation with minimal on-going maintenance. It utilizes ¼” tubing to seamlessly upgrade from legacy sample draw systems. Equipped with relay & analog outputs, this system can be digitally integrated into existing Building Management Systems (BMS).

Contact DOD Technologies to learn more and customize your system today!

Please click here for ChemLogic CL4 Replacement Cassette options. 

Gas Name LDL Full Scale Units
Ammonia (NH3) 1.2 75 ppm
Ammonia (NH3) 1.2 150 ppm
Arsenic Pentafluoride (AsF5) 0.2 10 ppm
Arsenic Trichloride (AsHCl3) 0.2 15 ppm
Arsenic Trifluoride (AsF3) 0.2 10 ppm
Arsine (AsH3) 2.2 500 ppm
Arsine (AsH3) 0.3 50 ppm
Boron Tribromide (BBr3) 0.1 20 ppm
Boron Trichloride (BCl3) 0.2 15 ppm
Boron Trifluoride (BF3) 89 3200 ppm
Boron Trifluoride (BF3) 89 10000 ppm
Bromine (Br2) 68.8 1000 ppm
Carbonyl Sulfide (COS) 0.9 20 ppm
Carbonyl Fluoride (COF2) 0.2 10 ppm
Chlorine (Cl2) 44.6 5000 ppm
Chlorine (Cl2) 50.1 3200 ppm
Chlorine (Cl2) 6.9 2000 ppm
Chlorine Trifluoride (ClF3) 0.2 10 ppm
Cyclohexane Diisocyanate (CHDI) 2.4 100 ppm
Diborane (B2H6) 6 1000 ppm
Dichlorosilane (SiH2Cl2) 0.2 15 ppm
Fluorine (F2) 49.8 3200 ppm
Fluorine (F2) 60 10000 ppm
Fluorine (F2) 41.6 10000 ppm
Fluorine (F2) 41.6 1000 ppm
Fluorosilicic acid (H2SiF6) 0.2 10 ppm
Germane (GeH4) 62.1 2000 ppm
Germanium Tetrafluoride (GeF4) 0.2 10 ppm
Hexachlorodisilane (SiCl2) 0.2 15 ppm
Hexafluorocyclobutene (C4F6) 1.5 40 ppm
Hydrazine (N2H4) 4.3 500 ppm
Hydrogen Chloride (HCl) 0.1 15 ppm
Hydrogen Chloride (HCl) 0.1 20 ppm
Hydrogen Bromide (HBr) 0.1 20 ppm
Hydrogen Cyanide (HCN) 298.2 2500 ppm
Hydrogen Fluoride (HF) 0.2 10 ppm
Hydrogen Fluoride (HF) 0.2 20 ppm
Hydrogen Selenide (H2Se) 5.1 500 ppm
Hydrogen Sulfide (H2S) 13.3 1500 ppm
Hydrogen Sulfide (H2S) 13.3 500 ppm
Hydrogen Sulfide (H2S) 10 90 ppm
Hydrogen Sulfide (H2S) 0.2 50 ppm
Hydrogen Sulfide (H2S) 0.2 20 ppm
Nitric Acid (HNO3) 187.5 5000 ppm
Nitrogen Dioxide (NO2) 0.3 100 ppm
Nitrogen Dioxide (NO2) 1.3 30 ppm
Nitrogen Trifluoride (NF3) 1 50 ppm
Phenyl Trichlorosilane (SiCl3Ph) 0.2 15 ppm
Phosgene (COCl2) 8.8 5000 ppm
Phosgene (COCl2) 8.8 3250 ppm
Phosgene (COCl2) 3.9 300 ppm
Phosphine (PH3) 4.8 300 ppm
Phosphine (PH3) 4.9 1500 ppm
Phosphine (PH3) 4.9 3000 ppm
Phosphorus Oxychloride (POCl3) 0.2 15 ppm
Phosphorus Pentachloride (PCl5) 0.2 15 ppm
Phosphorus Pentafluoride (PF5) 0.2 10 ppm
Phosphorus Tribromide (PBr3) 0.1 20 ppm
Phosphorus Trichloride (PCl3) 0.2 15 ppm
Phosphorus Trifluoride (PF3) 0.2 10 ppm
Silane (SiH4) 0.2 50 ppm
Silane (SiH4) 40 15000 ppm
Silicon Tetrachloride (SiCl4) 0.2 15 ppm
Stibine (SbH3) 14.6 500 ppm
Sulfur Dioxide (SO2) 19.3 2500 ppm
Sulfur Tetrafluoride (SF4) 0.2 10 ppm
Sulfuric Acid (H2SO4) 97.1 3200 ppm
Tertiary Butyl Arsine (TBA) 12 500 ppm
TDMAT 0.1 10 ppm
Tetrafluorosilane (SiF4) 0.2 10 ppm
Titanium Tetrachloride (TiCl4) 0.1 15 ppm
Tin Tetrachloride (SnCl4) 0.2 15 ppm
Toulene Diamine (TDA) 4 60 ppm
Trichlorosilane (SiHCl3) 0.2 15 ppm
Tungsten Hexafluoride (WF6) 0.2 10 ppm
More Information
BrandsDOD Technologies
Detection Points4
DisplayHMI
Intrinsically SafeYes
Detection PrincipleColorimetric
ManufacturerDOD Technologies
Product TypeGas Detectors
Product UseFixed
Detection RangeVaries by Gas (down to ppb)
Event Log StorageYES
BatteryNO
Power Requirements110VAC
AlarmsAudible & Visual
Operation Temperature40°F - 104°F | 4°C - 40°C