Tiger Select Portable Benzene Gas Detector

$4,730.00$5,780.00

Clear

Accessories / Options

The Tiger Select measures benzene selectively by use of a special sensor and a pre-filter tube in front of the PID to remove interfering chemicals present in fuel vapors.  A special mode is provided to measure total aromatics on a continuous basis. The Tiger Select Basic Instrument with 10.0eV Lamp includes: Li-ion Rechargable Battery, Battery Charger & Outlet Adaptor, Rubber Boot, Explorer Case (space for 44L or 116L Ecosmart Cylinder), USB Memory Stick, Draeger Benzene Pre-Filter Tubes & Tube Opener, Tiger Select Manual & Quick Start Guide, Carbon Filter Assembly & Adaptor, PTFE FIlter Discs, Removable Tool for MiniPID Stack, Sample Cleaning Compound, Lanyard & Sensor Seal)

Description

Tiger Select Brochure


Minimum Resolution

Select PPM
– Standard running mode 0.1 ppm
– TAC 0.01 ppm
– Tube Mode 0.001 ppm

Minimum Resolution
Select PPB
– Standard running mode 0.001 ppm
– TAC 0.001 ppm
– Tube Mode 0.001 ppm

Maximum Reading
– Standard mode 20,000 ppm or 20,000 mg/m3 (gas dependent)
– Tube mode 200 ppm or 639 mg/m3 benzene

Response Time
-120 seconds. Progressive indication of benzene breakthrough is displayed in real time.

Accuracy
– 10% display reading one digit benzene

Linearity
– 5% display reading one digit

Intrinsically Safe Approvals
– II 1G Ex ia IIC T4 Ga
– Tamb = -15c < Ta < +45c (With lithium ion battery pack)
– Tamb = -15c < Ta < +45c (With alkaline battery pack)
– ITS09ATEX26890X IECEx ITS 10.0036X
– 3193491 conforms to UL Std. 913, 61010-1
– Certified to CAN/CSA Std. C22.2 No. 61010-1

Battery Life
Li-ion: Life up to 24 hours, charge time 6.5 hours
Alkaline: 3 x AA, typically 8.5 hours of life

Lamps
10.0 Ev Krypton PID lamp

Data Logging
> 120,000 data log points including date and time stamp

Communication
Direct USB 1.1

Calibration
– 2 and 3 point calibration (via calibration kit accessory)

Alarm
– Flashing LED’s amber (low alarm, Red (high alarm)
– Sounder 95 dBA at 300 mm (12″) vibration on alarm
– Pre-programmed TWA and STEL

Flow Rate
> 220 ml/min

Temperature
– Operating -20 to 60 C, -4 to 140 F (non-intrinsically safe)
– Humidity 0-99% RH (non-condensing)

Protection
– Designed to IP65 (Heavy Rain)
– 1180
– EMC tested to EN61326-1:2006, EN50270:2006 & CFR 47:2008 Class A

Weight & Dimensions
– Instrument (probe fitted no tube attached)
– H x W x L: 18.3 x 3.5 x 2.4in
– Weight: .745 kg
– Packed Weight: 5 kg

Additional information

Weight 11 lbs
Dimensions 18.3 × 3.5 × 2.4 in
Units